Low voltage limiters P*G
LOW VOLTAGE LIMITERS
P60G, P120G (VLD-F)
![outdoor and indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000341-4b5304b531/P_120_G_50801-8.jpg?ph=52366262b6)
TYPE 1 VLD‑F
P60G, P120G - low voltage limiters Type 1 VLD-F based on requirements of EN 50122-1: 2011, which are designed to protect the non-live parts of metallic structures in DC or AC traction power supply systems. They are used to effectively protect persons who may come into contact with these parts during lightning strikes or in case of a defect of the tractive overhead line.
P600G
![outdoor and indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000341-4b5304b531/P_120_G_50801-8.jpg?ph=52366262b6)
P600G - power gas discharge tube (GDT) designed for potential equalisation on the installation components of buildings or technological units, which are not electrically connected to each other (according to EN 62305: 2011). It is recommended primarily for bridging of insulated flanges and insulated threaded joints in the pipeline cathodic protected parts of industrial technology.
LOW VOLTAGE LIMITERS
P60GI, P120GI (VLD-F)
![indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000353-7aa607aa62/P_60_GI_50800_I_.jpg?ph=52366262b6)
TYPE 1 VLD‑F
P60GI, P120GI - low voltage limiters Type 1 VLD-F based on requirements of EN 50122-1: 2011, which are designed to protect the non-live parts of metallic structures in DC or AC traction power supply systems. They are used to effectively protect persons who may come into contact with these parts during lightning strikes or in case of a defect of the tractive overhead line.
GAS DISCHARGE TUBE (GDT)
P600GI
![indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000353-7aa607aa62/P_60_GI_50800_I_.jpg?ph=52366262b6)
P600GI - power gas discharge tube (GDT) designed for
potential equalisation on the installation components of
buildings or technological units, which are not electrically
connected to each other (according to EN 62305: 2011). It is
recommended primarily for bridging of insulated flanges and
insulated threaded joints in the pipeline cathodic protected
parts of industrial technology.
LOW VOLTAGE LIMITERS
P250G, P400G (VLD-F)
![outdoor and indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000341-4b5304b531/P_120_G_50801-8.jpg?ph=52366262b6)
TYPE 1 VLD‑F
P250G, P400G - low voltage limiters Type
1 VLD-F based on requirements of EN 50122-1: 2011, which are
designed to protect the non-live parts of metallic structures
in DC or AC traction power supply systems. They are used to
effectively protect persons who may come into contact with
these parts during lightning strikes or in case of a defect of
the tractive overhead line.
LOW VOLTAGE LIMITERS
P250GI, P400GI (VLD-F)
![indoor use](https://52366262b6.clvaw-cdnwnd.com/00944e7d69093850bc183a5cc71f6a4a/200000353-7aa607aa62/P_60_GI_50800_I_.jpg?ph=52366262b6)
TYPE 1 VLD‑F
P250GI, P400GI - low voltage limiters
Type 1 VLD-F based on requirements of EN 50122-1: 2011,
which are designed to protect the non-live parts of metallic
structures in DC or AC traction power supply systems. They
are used to effectively protect persons who may come into
contact with these parts during lightning strikes or in case of
a defect of the tractive overhead line.